    ABB Drive help

    Im looking for some assistance with a, ABB ACS880-04-503A drive on a Daikin WDC centrifugal. Went to punch the tubes while its laid up for the winter. Discovered L1,L2 fuses blown. Looking for the propper checkout procedure. I was unable to locate anything published. I did a kind of generic...

    • View more comments
  • Member Post posted an update February 20, 2026

    February 20, 2026

    Trane CVHE450, 2003 Model, Overhaul 2017

    Looking for some advice on the following… Units needs the Motor windings temperature sensors replaced. Owner wants to do it in the field. Trane recommends to send the motor off to be redone.

    Has anyone replaced these in the field? Does Trane make a kit with the parts needed to epoxy them into the stator in the field?

    Member Post, Member Post and 5 others
    3 Comments
    • View more comments
  • Member Post posted an update March 6, 2026

    March 6, 2026

    Wsc063

    Hello

    could you support me with the following diagram? I’m having problems with a mcquay wsc chiller because of the low engine current problem, at the time of checking I found that the % rla does not go up from 0% and when I want to see the electrical diagram there is no information why it is destroyed

    Label 330273001

    Member Post, Member Post and 2 others
    7 Comments
    • View more comments
  • Member Post posted an update March 6, 2026

    March 6, 2026

    BLUEBOX

    Hi guys!

    I’m looking for some tech books, manuals or anything from which I could learn more about BlueBox by Swegon…Do you have any idea where could I find something useful?

    Tnx in advanced!

    Member Post, Member Post and Member Post
    4 Comments
    • View more comments
  • Member Post posted an update March 6, 2026

    March 6, 2026

    It should buff out lol

    Member Post, Member Post and Member Post
    0 Comments
  • Member Post posted an update May 20, 2025

    May 20, 2025

    @Member Post
    Hi Everyone.

    I had this call on a Trane CVHF870. Was tripped on oil differential.

    I checked the pompe on manuel = amp was ok, pressure was swinging, sight glasses empty. So I added 2.5 gallons of OEM oil and did the test again. The pressure got stable, oil level still not visible.

    Conditions: condenser water in was at 46°F

    I ran…

    Read more

    Member Post, Member Post and 2 others
    1 Comment
    • View more comments
  • Member Post posted an update February 26, 2026

    February 26, 2026

    Bitzer Compressor

    Would any have information on the start cycle for a Bitzer CSV screw compressor?

    About 10 seconds into the run cycle, a 230 volt 10 amp fuse is opening. Just trying to see what actually happens when its starts up. Its a VSD compressor.

    I have checked all the auxiliary solenoids within the heat-pump, panel fans etc but can’t seem to get to…

    Read more

    Member Post, Member Post and 3 others
    2 Comments
    • View more comments
  • Load More

Submit a Support Ticket

Are you facing a technical problem with the website or the online portal?
Submit a support ticket, and we will get back to you within 48 hours.

✓

Ticket Submitted!

Thank you! Your support ticket has been submitted. We will get back to you within 48 hours.

The Chiller Guys Hub

Join the Chiller Guys Community

Create a free account to keep reading and unlock full access to our community.

  • Access the full news feed & discussions
  • Share knowledge with like minded guys
  • Get exclusive training content
  • Join thousands of chiller mechanics worldwide