Member Post posted an update February 10, 2026
February 10, 2026 (edited)
OK, So its going to be one of THOSE days....
Went to do a Maintenance on an Airmec TBX2 Air-cooled Twin Turbocor today and got more than I bargained for. Standing Pressures seemed a bit low for R134a @+9°C so I ran my Leak detector around… It started to scream when I put it within half a meter of one of the compressors. It seemed to be coming from behind the Backplane so I thought…
0:18
Member Post, Member Post and 3 others1 Comment- View more comments
-
Member Post posted an update February 9, 2026
Motor temp sensors
Hello! Im wondering if anyone has experience with replacing the motor temp sensors on a CVHE in the field. I know they sale a replacement kit. Just wondering how much risk is involved. And if you have installed what approach was taken?
-
Member Post posted an update December 5, 2025
Rhoss Chiller
Would anyone have any information on Rhoss Chillers?
It is a YMD TCAEY 260, small Chiller 80KW or so.
HMI has an ‘A’ on it and no idea what it means. Can’t change anything on the HMI.
The Chiller is running, starting & stopping on demand, but just no idea what that means.
- View more comments
-
Member Post posted an update November 24, 2025
R410A recovery
Hello guys ، What are the steps and best methods to recover R410A refrigerant properly without causing refrigerant fractionation or blend separation issues? I want to avoid common problems like refrigerant fractionation during recovery. Any recommended procedures or tips for safe and effective recovery?
- View more comments
-
Member Post posted an update February 2, 2026
GWK chiller
Hello everyone,
Has anyone here worked with GWK chillers, specifically model WECO 300.1 AZ?
I’m facing a “Connection Error” alarm and would appreciate any support or guidance regarding troubleshooting or common causes.
Thanks in advance.- View more comments
-
Member Post posted an update January 27, 2026
Trane CVHF570 2008 – just overhauled and installed new earthwise purge and cannot get sensors to bind, had them binded once but lost comm after power cycle
- View more comments
-
Member Post posted an update January 2, 2026
Please help me,
“What is the purpose of using an economizer in an air-cooled chiller?”
- View more comments
-
Member Post posted an update January 21, 2026
Anny one familiar with emicon/hidros/enex products?
- View more comments
-
Member Post posted an update January 20, 2026
Refrigerant Compliance Guide
I got this EPA Compliance guide from FM hero today, figured it might be useful for some that are working in industrial facilities that need to keep a tight ship with documentation for the EPA.
I also uploaded a copy of it to the member files as well.
Hopefully everyone is having a good new year so far.