  • Member Post posted an update June 18, 2026

    June 18, 2026

    5H40 SUPERHEAT

    I have two 5h40 tandem system water cooled with DX coil , what is the good number for super-heat , I thought between 16-18 degree or 10-12 degree is better ?

    Member Post
    1 Comment
    • View more comments
  • Member Post to Member Post June 17, 2026

    June 17, 2026

    Training

    Working my way through the courses here. Any update on when Step 3 for air cooled troubleshooting will be ready. Really enjoying the site and all the classes so far. Thanks. @Member Post Post

    Member Post, Member Post and 3 others
    0 Comments
  • Member Post posted an update March 23, 2026

    March 23, 2026

    I have not had the opportunity to disassemble a float valve for a 19xr. I’m pretty familiar with float mechanisms but I just need clarity on how this particular valve works. Are we trying to maintain a discharge superheat? Does anyone have specifics in regards to detailed parameters affecting the flow valve? I’m assuming if we’re maintaining… Read more

    Member Post, Member Post and 2 others
    1 Comment
    • View more comments
  • Member Post posted an update June 14, 2026

    June 14, 2026

    Member Post, Member Post and 3 others
    0 Comments
  • Member Post posted an update June 13, 2026

    June 13, 2026

    Please lhis error in chiller career

    Member Post and Member Post
    2 Comments
    • View more comments
  • Member Post posted an update June 13, 2026

    June 13, 2026

    Hi

    Member Post
    0 Comments
  • Member Post posted an update June 12, 2026

    June 12, 2026

    Looking at a Trane HDWA300. Curious what the ideal inlet condenser water temperature should be? Its a mag so i imaging 85 may be too high.

    Member Post and Member Post
    0 Comments
  • Member Post posted an update June 12, 2026

    June 12, 2026

    AWV compressor vfd output high

    Issue with two AWV’s where line side of breaker for both units had cables stolen. After cables were replaced I’m running into issues with the output side of the VFDs having high amps and compressors are unable to stage up with the high amp draw. One unit is using Yaskawa A1000 drives and the other is using Danfoss VLT drives. I can see in the…

    Read more

  • Member Post posted an update June 8, 2026

    June 8, 2026

    Trane SFHC package unit

    I’ve got 8 Trane SFHC from 1990 and I cant seem to find a period correct manual for them. Just got this account and all of them are down. It looks like a controller issue but I am unable find manuel and trane wont help due to us being competitors. Any help would be appreciated.

    Member Post and Member Post
    5 Comments
    • View more comments
  • Load More

Submit a Support Ticket

Are you facing a technical problem with the website or the online portal?
Submit a support ticket, and we will get back to you within 48 hours.

✓

Ticket Submitted!

Thank you! Your support ticket has been submitted. We will get back to you within 48 hours.

The Chiller Guys Hub

Join the Chiller Guys Community

Create a free account to keep reading and unlock full access to our community.

  • Access the full news feed & discussions
  • Share knowledge with like minded guys
  • Get exclusive training content
  • Join thousands of chiller mechanics worldwide