Member Post posted an update
Anyone provide me schematics of this carrier scpm board 32gb500402ee
Ive some board imported from china and customers say it is showing current embalance error like 308 if side b installed with dip swich configure as 30gx and mta as compressor 06na setting and star delta to 1000.
Like comprassor starts and off with error 107/108 a installed and 307/308 side b installed
Even ive replaced the Current CT and current CT jack clean it out as replaced scpm board things works smooth.
But we need to fix our board and i need schematics to find flow error so that i can replace triacs, mosfets and other things on it.
1 Comment-
post this in a private group, so the guys get an email notification. the public posts only go to your connections.
-