  • Member Post posted an update May 19, 2025

    May 19, 2025

    @Member Post
    Working on a yk and found the division plate rotted straight through.

  • Member Post posted an update May 17, 2025

    May 17, 2025

    @Member Post
    Hi all! I just wanted to introduce myself and share a photo I took YMC 2 over at intuit dome in Inglewood ca. we take care of the maintenance on them.

    Member Post and Member Post
    0 Comments
  • Member Post posted an update May 16, 2025

    May 16, 2025

    @Member Post
    I am by no means a “chiller tech” yet. Came across this chiller last week during an inspection. Logging info and visually checking things out. Needless to say the strainer needed cleaning.

    What should this YK evap approach be? The chiller next to this one had an evap approach of 1. Pressure differential on both chillers was 8.

    Member Post, Member Post and 2 others
    3 Comments
    • View more comments
  • Member Post posted an update May 15, 2025

    May 15, 2025

    @Member Post
    I think compressor replacement is in the future

    YCAV

    Member Post
    0 Comments
  • Member Post posted an update May 11, 2025

    May 11, 2025

    I have a scroll water cooled York 410a chiller with relief valves on the condenser barrel rated for 560psi. What’s the reason for 560psi? Usually I put 600psi reliefs on 410a systems.

    Member Post
    3 Comments
    • View more comments
  • Member Post posted an update May 8, 2025

    May 8, 2025

    I have a York YK that is displaying thus fault. It supposed to be auto restart once the fault clears. It went down yesterday afternoon and I guess it never came back online. What should I be checking?

    Member Post
    17 Comments
    • View more comments
  • Member Post posted an update May 7, 2025

    May 7, 2025

    Hey guys. I’m working on a trane rtac184 ton. This plant keeps having issues where the chillers compressor for each circuit 1&2 will continuously cycle on and off but no faults come in whatsoever. While I’ve monitored both chillers ive seen nothing abnormal really. Has anyone experiwnced these type of issues?

    • View more comments
  • Member Post posted an update May 7, 2025

    May 7, 2025

    Welcome to the jungle 🤟

    Member Post and Member Post
    1 Comment
    • View more comments
  • Member Post posted an update May 1, 2025

    May 1, 2025 (edited)

    @Member Post
    “Has anyone made their own subcooler for recovery? I started making one with 1/2 pipe, but am looking for ideas on how to make a shell for it so it has more durability, also to space out the loops.”

    • View more comments
  • Load More

Submit a Support Ticket

Are you facing a technical problem with the website or the online portal?
Submit a support ticket, and we will get back to you within 48 hours.

✓

Ticket Submitted!

Thank you! Your support ticket has been submitted. We will get back to you within 48 hours.

The Chiller Guys Hub

Join the Chiller Guys Community

Create a free account to keep reading and unlock full access to our community.

  • Access the full news feed & discussions
  • Share knowledge with like minded guys
  • Get exclusive training content
  • Join thousands of chiller mechanics worldwide