  • Member Post posted an update July 27, 2026

    July 27, 2026

    23xl. I’ll loss prevention alarm

    Ive been working on a 23xl2323 s# 4300q64626. R 22 machine. I originally went to call of leak and oil on ground. Small leak and small puddle on floor.repaied leak. And alarm came up when started chiller.i changed oil filter and still had alarm.checked all sensors solenoids ect. Pulled refrigerant and its 70 pounds low.pulled out oil and got…

    Read more

    Member Post and Member Post
    0 Comments
  • Member Post posted an update July 23, 2026

    July 23, 2026

    Smardt Air Cooled AD120

    Hey everyone need a little help. Got myself infront of a Smardt AD120 and I’ve got an alarm for compressor 2 overcurrent rotor may be locked. This has the danfoss turbocor TTS350 in it. And I’m not the most proficient with the turbocors. Only worked on them a handful of times and it was maintenance related for everything else on those. Way…

    Read more

    Member Post
    2 Comments
    • View more comments
  • Member Post posted an update July 11, 2026

    July 11, 2026

    Turbocor Compressor Touchdown Bearing Issue

    Hi Guys,

    I would like to ask, if what is the causes that damage the Touchdown Bearings of a Turbocor Compressor?

    Thank you,

    Member Post, Member Post and 4 others
    5 Comments
    • View more comments
  • Member Post posted an update June 19, 2026

    June 19, 2026

    Looking For Some Advice

    We are in the process of making some updates to the portal, and I am looking for some advice on how to prioritize the updates we make so you guys get the most use out of the portal on the job.

    Select an option below, or add one that you want to see:

    What should we prioritize?

    4.88%
    92.68%
    2.44%
    0%
    0%
    0%
    0%
    This is already an option
    Love
    Member Post, Member Post and Member Post
    7 Comments 1 Share
    • View more comments
  • Member Post posted an update July 16, 2026

    July 16, 2026

    Teardown Manual for McQuay WSC087

    Hi everyone, im looking for a compressor teardown manual for a McQuay WSC087 (or Daikin as they are now) my manuals havent stood the test of time and have water perished 🤬….Any assistance be appreciated 👍🏻

    Thank You – BC

    Member Post and Member Post
    6 Comments
    • View more comments
  • Member Post posted an update July 12, 2026

    July 12, 2026

    AMOT Valves on Older York Chillers

    Older York chillers used AMOT valve. As long as i worked around York’s i never dug into operation and maintenance of AMOT valves. Anyone have any input?

    Member Post, Member Post and 5 others
    18 Comments
    • View more comments
  • Member Post posted an update July 15, 2026

    July 15, 2026

    Trane RTAC

    Has anyone changed the ribbon cable to the global connector cable on an RTAC. If so are the transducers on schraders or does the machine have to be recovered to replace. Thanks in advance

    Member Post
    3 Comments
    • View more comments
  • Member Post posted an update July 16, 2026

    July 16, 2026

    Oil analysis

    Does anyone have any recommendations for companies that perform oil analysis for screw compressors? I am a York factory trained chiller mechanic that no longer works for JCI. I miss having their predictive maintenance dept support me. Thanks in advance.

    Member Post, Member Post and Member Post
    0 Comments
  • Member Post posted an update July 8, 2026

    July 8, 2026

    I have a 500 ton York YK chiller thats getting a Harmonic Filter-Logic Board or Communications shutdown. I disabled the Harmonic Filter because we were in the middle of a heat wave. Unit started and has been running. Does anyone know how to troubleshoot this alarm. The manual doesn’t give much direction. Any help would be greatly appreciated. Thanks

    Member Post and Member Post
    4 Comments
    • View more comments
  • Load More

Submit a Support Ticket

Are you facing a technical problem with the website or the online portal?
Submit a support ticket, and we will get back to you within 48 hours.

✓

Ticket Submitted!

Thank you! Your support ticket has been submitted. We will get back to you within 48 hours.

The Chiller Guys Hub

Join the Chiller Guys Community

Create a free account to keep reading and unlock full access to our community.

  • Access the full news feed & discussions
  • Share knowledge with like minded guys
  • Get exclusive training content
  • Join thousands of chiller mechanics worldwide